Shop with confidence! This product has been fully inspected to avoid any buyer surprises. Read our in-depth product listing below.
Your purchase will NOT include: This product is pre-owned and may not include the same accessories as a new, unused unit. - other accessories not shown or listed here.Prior to testing this autoclave, the major components were inspected and tested and found to be functioning normally. Then the Reservoir Tank was cleaned and flushed and a new Safety Valve, Condenser Coil, Air Jet Valve and Reservoir Cap were installed. Cleaned the sterilizing chamber and installed a new Door Gasket and Door Bellows Assembly. Also installed a new Power Switch. Cleaned the sterilizing trays and rack. To test this autoclave, it was first connected to a 120 volt power source, distilled water was added, it was then properly levelled as per it's chamber size requirement and then testing began. This sterilizer was run through cycles of 270 F for 10 minutes and 250 for 30 minutes several times. To verify that this autoclave is achieving it's maximum required sterilizing temperature during a cycle, it was temperature tested with the use of a Max Register Thermometer, and found to exceed 270 F during a sterilization cycle.
Prior to testing this autoclave, the major components were inspected and tested and found to be functioning normally. Then the Reservoir Tank was cleaned and flushed and a new Safety Valve, Condenser Coil, Air Jet Valve and Reservoir Cap were installed. Cleaned the sterilizing chamber and installed a new Door Gasket and Door Bellows Assembly. Also installed a new Power Switch. Cleaned the sterilizing trays and rack. To test this autoclave, it was first connected to a 120 volt power source, distilled water was added, it was then properly levelled as per it's chamber size requirement and then testing began. This sterilizer was run through cycles of 270 F for 10 minutes and 250 for 30 minutes several times. To verify that this autoclave is achieving it's maximum required sterilizing temperature during a cycle, it was temperature tested with the use of a Max Register Thermometer, and found to exceed 270 F during a sterilization cycle.
- Manufacturer: Tuttnauer
- Model: 2340M
- Serial Number: 14070863
- Power Requirements: 120V
- Year: 2014
- Timer Function: Not available
- Controls: Not available
- Cycle Count: Not available
- Software Version:
1 - Tuttnauer 2340M Manual Autoclave Steam Sterilizer 3 - Sterilizing Trays w/ Rack 1 - Drain Hose 1 - Power Cord
Item Excludes:
This product is pre-owned and may not include the same accessories as a new, unused unit.
-
Identify the Equipment You Need
Browse our online catalog for New, Certified Pre-Owned and used dental equipment from trusted manufacturers. Each listing includes detailed specifications, condition reports, and photos to help you choose the right equipment for your practice.
-
Reserve Your Equipment
Once you’ve identified the right equipment for your practice, click to reserve the equipment. We’ll place the item on hold for 48 hours, giving you time to finalize your decision without the risk of someone else purchasing it.
-
Work With Your Henry Schein Representative
After you reserve the equipment, we’ll automatically notify your Henry Schein representative. They’ll follow up with an official quote and invoice, and will help guide you through payment, install, and delivery options.



